CHAIN COUNTER
CHC 1103 B
CHC 1103 B is a complete and reliable instrument for remotely operating the windlass and checking the length of the chain lowered by means of the graphic LCD display.
CHC 1103 B is made with rubber inserts to ensure high resistance, durability, perfect waterproofness and a secure grip.
Cable is extendable up to 4.2 meters
Waterproof connector
Support bracket for storage after use.
Available with integrated LED torch as standard.
Also usable in towing operations.
It requires no maintenance.
General characteristics
- Simple and intuitive user interface.
- Display indications in 5 languages.
- Automatic descent function.
- Uphill alarm function.
- Key lock function.
- Can be used in towing operations.
- Automatic free fall windlass management.
- Anchor recovery feature in case of non-functioning sensor.
- Display of chain movement speed.
- Display of supply voltage.
- Display of the chain length dropped in meters, feet or fathoms.
- Indication of remaining chain on board.
- Graphic LCD display with high viewing angle.
- Display backlighting adjustable to 5 intensity levels.
- Display contrast adjustable to 5 levels.
- Automatic compensation of display contrast based on ambient temperature.
- Universal power supply (12/24Vdc).
- Backlit operating buttons.
- Equipped with LED torch.
- CAN bus interface for data transfer.
- Operation over a wide ambient temperature range.
- Waterproof container.
Model | CHC 1103 |
Current carrying capacity of UP/DOWN contacts | 4A max |
Supply voltage (1) | 9 ÷ 32 Vdc |
Quiescent current consumption (2) | 12mA @ 12V - 8mA @ 24V |
Maximum absorption (3) | 91 mA + contactor coil absorption |
Operating temperature (4) | from -20 to +70 °C |
Degree of protection (5) | IP 67 |
Communication interface | CAN bus with differential transceiver |
Weight - g | 750 g |
EMC Class | EN 60945 - FCC Part 15 Rules 47 |
1) | The instrument can reset if the supply voltage is lower than 9 Vdc. |
2) | Typical value with backlight and torch off and windlass not activated. |
3) | Typical value with backlight active at maximum level, torch on and windlass activated. |
4) | At temperatures below 0°C the crystals of the LCD display slow down their movement. |
5) | With the plug correctly inserted into the socket. Excluding the area of the socket where the output cable is welded (IP 00). |