MASTERVOLT INVERTER AC MASTER 12/500
Couldn't load pickup availability
SHARE ON
AC Master 12/500 IEC (230V)
Safe AC power for recreational and semi-professional use
These affordable pure sine wave inverters convert 12V or 24V battery power into stable 230V 50/60Hz or 120V 50/60Hz grid power, making them ideal for recreational and semi-professional applications. The AC Master series inverters are easy to install and provide maximum power even in difficult conditions. The pure sine waveform ensures the highest quality power, essential for the operation of sensitive equipment. The use of high-frequency switching technology eliminates any noise due to vibrations and hums.
These solid inverters provide the comforts of home when you are away from the grid, with an excellent quality/price ratio.
Characteristics
- Pure sine wave protects sensitive equipment.
- They deliver full power and high peaks even in difficult conditions.
- Automatic energy saving system for long-term use.
- Easy to install: IEC socket and plug included.
- Reliable and safe: protected against overtemperature, overload, short circuit, high and low battery voltage.
Applications
Both recreational and semi-professional use, where there is a shortage or absence of the electrical network. Applications include: lighting, household appliances, electric kitchens and tools. For (mobile) applications at home, in the office, in service vehicles, or during vacations.
Specifications
General Specifications | ||
Output voltage | 200/220/230/240 V – 50/60 Hz (adjustable) | |
Output waveform | pure sinusoidal | |
Nominal battery voltage | 24V | |
Recommended battery capacity | ≥ 50Ah | |
Continuous power at 25 °C / 77 °F, cos phi 1 | 700W | |
Continuous power at 40 °C / 104 °F, cos phi 1 | 700W | |
Peak power (1 min.) | < 810W | |
Peak power (1 s) | < 1230W | |
AC Connection | EU type socket (Schuko), with UK plug (art.n. 28220700) or with NZ/AU plug (art.n. 28420700) | |
Galvanic isolation | Yes | |
Efficiency | 93% | |
Display/readings | LED indicators: battery voltage, AC load level and status | |
Alarms | clean alarm contact | |
Dimensions, hxwxd | 200 x 330 x 83 mm 7.9 x 13.0 x 3.3 inches |
|
Weight | 2.7 kg 6.0 lbs |
|
Certifications | CE, E-mark, RCM | |
Technical specifications | ||
Technology | high frequency, isolated input and output | |
Low battery voltage shutdown | 21 V | |
Low battery voltage recovery | 25 V | |
High battery voltage shutdown | 33 V | |
High Battery Voltage Recovery | 29 V | |
Current draw (at rated load) | 35 A | |
Self-consumption (ON mode) | < 0.8 A | |
Self-consumption (energy saving mode) | < 0.06 A | |
Minimum DC fuse size (slow blow) | 50 A | |
Minimum cable section | 16mm² | |
Harmonic distortion (typical) | < 5 % | |
What is phi? | all cos phi allowed | |
Room temperature | -20°C to 60°C, power reduction > 40 |
|
Cooling | Temperature and load controlled fan | |
Degree of protection | IP21, horizontal wall mounting | |
Protections | over temperature, overload, short circuit, high/low battery voltage, reverse polarity (fuse) | |
MasterBus compatible | yes, via a MasterBus AC Master Interface | |